Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

Digital Multimeter APPA 106

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Lusin
Dilihat Sebanyak
:
11 kali
Harga
Rp. 2.220.000
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Digital Multimeter APPA 106

Digital Multimeter APPA 106 Features : 4000 count digital display 82-segment analogue bargraph display data-hold function relative measuring mode min/ max/ avg function peak hold continuity check/ beeper backlight open communication protocol water and dust-resistant protective holster true RMS Spesifikasi - Digital Multimeter APPA 106 Specifications Voltage AC APPA 103N Range: 400.0mV~ 750V Basic Accuracy: + / -( 1.3% + 5d) APPA 105N, 106 Range: 400.0mV~ 750V Basic Accuracy: + / -( 1.0% + 5d) APPA 107N, 109N Range: 400.0mV~ 750V Basic Accuracy: + / -( 0.7% + 5d) APPA 103N, 105N Conversion Type: Average sensing RMS indicating APPA 106 Conversion Type: True RMS reading on AC mode APPA 107N, 109N Conversion Type: ( AC+ DC) True RMS reading on AC mode ACV spec. + 1.00% + 8d Input Impedance: 10M? / / 100pF APPA 103N, 105N, 106 Frequency Resonse: 40Hz~ 1kHz APPA 107N Frequency Response: 40Hz~ 50kHz APPA 109N Frequency Response: 40Hz~ 100kHz Overload Protection: 1000V DC or 750V rms Voltage DC APPA 103N Range: 400.0mV~ 1000V Basic Accuracy: + / -( 0.25% + 1d) APPA 105N, 106 Range: 400.0mV~ 1000V Basic Accuracy: + / -( 0.1% + 1d) APPA 107N, 109N Range: 400.0mV~ 1000V Basic Accuracy: + / -( 0.06% + 10d) Input Impedance: 10M? Overload Protection: 1000V DC or 750V rms Current AC APPA 103N, 105N, 106 Range: 40.00mA~ 10A Basic Accuracy: + / -( 1.3% + 5d) APPA 107N, 109N Range: 40.00mA~ 10A Basic Accuracy: + / -( 0.8% + 50d) APPA 103N, 105N Conversion Type: Average sensing RMS indicating APPA 106 Conversion Type: True RMS reading on AC mode APPA 107N, 109N Conversion Type: ( AC+ DC) True RMS reading on AC mode ACV spec. + 1.00% + 8d APPA 103N, 105N, 106 Frequency Resonse: 40Hz~ 1kHz APPA 107N, 109N Frequency Response: 40Hz~ 3kHz Input Protection: Equipped with High Energy Fuse. 1A, 600V, IR 10KV fuse for mA input 15A, 600V, IR 100KV fuse for A input Current DC APPA 103N, Range: 40.00mA~ 10A Basic Accuracy: + / -( 0.6% + 2d) APPA 105N, 106 Range: 40.00mA~ 10A Basic Accuracy: + / -( 0.4% + 2d) APPA 107N, 109N Range: 40.00mA~ 10A Basic Accuracy: + / -( 0.2% + 40d) Input Protection: Equipped with High Energy Fuse. 1A, 600V, IR 10KV fuse for mA input 15A, 600V, IR 100KV fuse for A input Resistance APPA 103N Range: 400.0? ~ 40.00M? Basic Accuracy: + / -( 0.6% + 2d) APPA 105N, 106 Range: 400.0? ~ 40.00M? Basic Accuracy: + / -( 0.4% + 2d) APPA 107N, 109N Range: 400.0? ~ 40.00M? Basic Accuracy: + / -( 0.3% + 30d) Overload Protection: 600V rms Continuity Beeper APPA 103N, 105N, 106 < 50? , 2k Hz tone buzzer APPA 107N, 109N < 150? , 2k Hz tone buzzer Diode Test APPA 103N, 105N, 106 Open circuit voltage: 3V APPA 107N, 109N Open circuit voltage: 3.3V Capacitace APPA 103N, 105N, 106 Range: 4.000nF~ 10mF Basic Accuracy: + / -( 2.0% + 5d) APPA 107N, 109N Range: 4.000nF~ 10mF Basic Accuracy: + / -( 0.9% + 5d) Overload Protection: 600V rms Frequency Counter APPA 103N, 105N, 106 Range: 4kHz~ 400MHz Basic Accuracy: + / -( 0.01% + 1d) APPA 107N, 109N Range: 20.00Hz~ 1MHz Basic Accuracy: + / -( 0.01% + 10d) Overload Protection: 600V rms RPM APPA 103N, 105N, 106 Range: 40kRPM~ 400kRPM Basic Accuracy: + / -( 0.01% + 10d) Overload Protection: 600V rms Duty Factor APPA 107N, 109N Range: 20% ~ 80% Basic Accuracy: + / -1% Temperature APPA 106 Range: -20C~ 800C Basic Accuracy: + / -( 2% + 2C) at 351C~ 500C APPA 107N, 109N Range: -200? ~ 1200? Basic Accuracy: + / -( 0.1% + 3C) at -100C~ 1200C Overload Protection 600V rms General Specifications Display APPA 103N, 105N, 106 4000 count, 82 segment analog bargraph APPA 107N, 109N 20000count/ 4000 count , 83 segment analog bar graph Measuring Rate APPA 103N, 105N, 106 2.5times/ sec for 4000 count and 20 times/ sec for analog bargraph APPA 107N, 109N 2times/ sec for 20000 count, 4times/ sec for 4000 count, and 20times/ sec for analog bargraph Overload Indication Auto Power Off " OL" or " -OL" Operating Temperature -20C~ 50C, < 80% RH Storage Temperature -20C~ 60C Temperature Coefficient 0.15( Spec. Acc) / , 28C Safety IEC61010 and designed to meet UL61010 specifications Power Requirement APPA 107N, 109N IEC 6LF22, 6AM6 or NEDA 1604A 9V x1 APPA 103N, 105N IEC LR03, AM4 or AAA size 1.5V x 2. Battery Life APPA 103N, 105N 450 hours ( Alkaline) APPA 106 300 hours ( Alkaline) APPA 107N, 109N 100 hours ( Alkaline) Size 86mm ( W) x 185mm ( L) x 31.5mm ( H) 98mm ( W) x 197mm ( L) x 50mm ( H) with holster Weight 620 grams Included with Instrument Protective holster, test leads, test clips, ZnC battery( Installed) , manual, Optical USB cable( 109N) , and WinDMM 100S( 109N
Tampilkan Lebih Banyak